Product Details:
Payment & Shipping Terms:
|
Material: | Stainless Steel | Temperature Range: | -40℃~+150℃ |
---|---|---|---|
Humidity Range: | 20%~98%R.H. | Heat Up Time: | -70℃~+100℃(within 60 Min) |
Pull Down Dime: | +20℃~-80℃(within 80 Min) | Power Supply: | AC 3 Phase 380V 60/50Hz |
High Light: | temperature and humidity chamber,temperature test chamber |
Fully Automatic Stainless Steel Temperature Humidity Test Chamber For Electronic Products
Ⅰ. Overview | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Able to temperature control accurately and wide range of control, and is suitable for reliability test in industrial products. Meet GB5170.2.3.5.6-95 standard requirements of environmental testing equipment and test methods for the basic parameters of electric and electronic products under the condition of humidity, low temperature, high temperature, and constant heat. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ⅱ. Application | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
It is suitable for quality and reliability testing of products, parts and materials under high temperature conditions for electrical, electronic, mechanical and other products, parts and materials. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ⅲ. Features | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
● GB-2423.1-2008 (IEC68-2-1) Test A: Low Temperature Test ● GB-2423.2-2008(IEC68-2-2) Test B: High Temperature Test ● GJB360.8-2009(MIL-STD.202F) High Temperature Operating Life Test ● GBJl50.3-2009(MIL-STD-810D) High Temperature Test ● GJBl50.4-2009(MIL-STD-810D) Low Temperature Test |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. user-friendly control |
※KOMEG Programmable KM-5166 LCD Touch Screen Controller with PID control parameters setting ※Flexible approach for data collection and recording |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. High reliability |
※Key Parts are imported to ensure the service life and high reliability; ※ Efficient oil separator to ensure the compressor life. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ⅳ. Main Technical Index | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. Temp. Range | -40℃~+150℃ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Temp. Deviation | ±2.0℃ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3. Temp. Uniformity | ±2.0℃ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4. Temp. Fluctuation | ±0.5℃ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5. Heating Rate | -70℃ ~ +100℃ Non-linear 2℃/ min (no load) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
6. Cooling Rate | +20℃ ~ -80℃ Non-linear 1℃/ min (no load) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
7.Humidity Range | 20%~98%R.H. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ⅴ. Body Structure |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Interior size |
W 200×H 220×D 250 mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
External Size |
W 230×H 260×D 425mm(Does not contain the machine protruding part) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
External material |
High-quality carbon steel plate, the surface for electrostatic color spray treatment | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Interior material |
stainless steel | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Insulation material |
150mm rigid polyurethane foam | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Floor load bearing |
Floor reinforcement, the bottom bearing more than 1500kg | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Door |
Double doors, door size W(1000+1000)*H2000mm, Windows W460*H560 mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Threading hole |
Open a φ300mm hole in the left side of the chamber, also equipped with rubber isolation plug and plastic cover. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Lighting Device |
2 damp-proof lighting , with explosion-proof lampshade | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power distribution control cabinet | Total power circuit breaker, over-temperature protection | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Heating |
High-quality nickel-chromium alloy wire heater, non-contact control mode (SSR) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pressure balance port | The test chamber have a type 1 pressure balance port, to ensure the pressure balance of the laboratory inside and outside | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Slope | Slope 1 type, easy access to test items | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ⅵ. Air Conditioning System | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Compressor |
Germany Bock semi-compact compressor | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Refrigerant |
Non-fluorine environmental friendly refrigerant: R404a R23, in line with environmental regulations, safe non-toxic | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Condenser |
Shell-and-tube condenser (water-cooled) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Evaporator |
Multi - stage Automatic Load Capacity Adjustment | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
other attachments |
High-precision expansion valve, desiccant, and other components are imported internationally famous brands. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Expansion system |
Multi-stage adjustable energy consumption output control of the refrigeration system | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Refrigerant flow control |
Automatic adjustment of energy consumption output control of the refrigeration system | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Refrigeration process |
※ Full implementation of nitrogen protection welding, two-stage rotary vane pump vacuum, to ensure that the refrigeration system internal clean,reliable; ※ The bottom of the compressor design water tray, the condensate through the rear of the tank drain to the box outside the box. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ⅶ. Control System | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
High precision DIN A class, Dry ballφ4.8mm SUS #304 PT 100Ω. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2.Controller |
KOMEG Programmable KM-5166 LCD Touch Screen Controller with PID control parameters setting
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3.Language | Chinese / Russian | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4.Display Function |
Temperature and humidity settings (SV) Practical (PV) value can be displayed directly; Execution of the program can display numbers, paragraphs, remaining time and cycles, running time display, Program editing and graphic curve display, Fixed or program operation status display, Resolution: 800*480, 7-inch TFT display screen. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5.Display Resolution |
Temperature: + 0.01℃; Humidity: + 0.1%; time: 1min. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
6.Setting Range |
Temperature conditions:–100~200 ℃; Temperature can be adjusted based on the working temp. range of the equipment (the upper limit: +5℃, the lower limit : -5℃) Humidity conditions:0~100 %RH. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
7.Operation Mode | Programmable running, constant running | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
8. Program capacity |
Set the running time to reach 9999 h 59 m(Set 0 to constant operation without time limit); Available program capacity: Up to 1000 groups; The memory capacity that can be used: Each group of 1000 times (step); Repeated commands: Each command can be up to 999 cycles. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9. Setting Mode | Man - machine dialogue mode,Touch Mode Input and control. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10. Communication Interface |
Data collection and curve display when connected to a computer Can be used as monitoring and remote control system Multiple machines synchronization control available RS-232,RS-485 and Ethernet. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11. U Disk Memory Card | 1G-8G available for downloading historical curve, data, pluggable | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12. Data Collection |
RAM with battery protection, setting(SV), Practical(PV) and sampling time can be saved; The curve recording period can be set 10~60 sec. Maximum historical data memory storage is 90 days, historical data(When sampling). |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13. Power Off Memory Function | Power recovery mode can be set as hot start, cold start and stop | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14. Pre-set Function | Boot time can be set freely and machine runs automatically when turning on power | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15. Software Environment | Windows 2000 or Windows XP | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16. Network Connection | Can be connected to Ethernet via professional software, remote control & assistance function and data collection can be achieved through network, , multiple machine can be controlled simultaneously | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ⅷ. Control panel | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
a. Emergency stop switch b. switch c. Over-temperature protector d.RS-485 interface |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ⅸ. Protection System | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
a. Leakage switch; b. Heater burnout protection switch; c. Circulating fan over current overload protection; d. Compressor overpressure protection; e. Compressor motor overheating protection; f. Compressor motor over-current protection; g. Overvoltage owe anti-phase protection h. Breaker |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ⅹ. Installation Environment | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.Power
|
AC 3ψ4W 380V 50HZ(R.S.T.N add ground wire)( Voltage fluctuation≦±10%) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2.Surrounding Environment | Guaranteed operating ambient temperature rang:5〜35℃ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Contact Person: Anna Hu
Tel: +8618098282716