Standard / Custom Solid Walk-in chamber for photovoltaic modules testing

Standard / Custom Solid Walk-in chamber for photovoltaic modules testing
Standard / Custom Solid Walk-in chamber for photovoltaic modules testing
video play

Large Image :  Standard / Custom Solid Walk-in chamber for photovoltaic modules testing

Product Details:
Place of Origin: China
Brand Name: KOMEG
Certification: CE/ROHS/FCC/
Model Number: KMHW-13
Payment & Shipping Terms:
Minimum Order Quantity: 1set
Price: negotiation
Packaging Details: Packed in carton firstly,and then reinforced with wooden case for outer packing
Delivery Time: 40 working days after received your payment
Payment Terms: T/T /C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow
Supply Ability: 50 sets per month
Detailed Product Description
Product Name: Walk-in Chamber Volume(M3): 27.1CBM
Temp. Constancy: +/-0.5oc Humidity Constancy: +/-2.5%R.H
Controller: LCD Touch Panel Delivery: 40 Working Days
Interior Dimensions: W3000 X H2100 X D4300mm Refrigeration System: Water Cooled
High Light:

walk in environmental chamber

,

walk in climatic chamber

 
Standard / Custom Solid Walk-in chamber for photovoltaic modules testing
 
1. Applications
 
A KOMEG Walk-In Chamber serves as a test site for large components, assemblies, and finished products. KOMEG manufactures both Panel Walk-In Chambers and Solid Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber.
 
A Panel Walk-In Chamber is made from lightweight insulated panels for fast and easy installation. Usually for electronics temperature aging, like recharger, PCBA, Battery, LCD, scanners, monitors, LED, biological equipment,etc. Outside banding helps prevent leaking and keeps moisture out of the Walk-In Chamber and workspace temperatures steady.
 
Solid Walk-In Chambers are custom built to accommodate almost any size. They feature welded walls creating an environmental room for applications requiring controlled temperature and humidity testing exceeding 85°C. Typically, for ease of installation, a Solid Walk-In Chamber works best in new construction buildings, areas with extremely large doors, or rooms where outside walls can be easily removed.
 
 
2. Standard Implemented and Met:
 
Inspect standard: JJF-1101, GB/T 10592,GB/T 10586
Testing standards:
YD/T 2061, HB 7122.3, 6783.7, GJB 5382.7, GJB 150, GB/T 2423,5170.2,5170.5,5179.2, ASTM E512, NF EN 60068-2-38, CNS 12565,12566, KS C0227, KS C022
 

 
3. Main Technical Parameters

SPECIFICATIONS  
Model KMHW-
4 6 8 13 17 21
Volume(m³) 9 12.9 16.8 16.8 35.2 43.3
Interior Dimensions W(mm) 2100 3000 3900 3000 3900 4800
H(mm) 2100 2100 2100 2100 2100 2100
D(mm) 2050 2050 2050 4300 4300 4300
Exterior Dimensions W(mm) 3250 4160 5050 5050 5050 5950
H(mm) 2350 2350 2350 2350 2350 2350
D(mm) 2250 2250 2250 2250 4500 4500
Control System Balanced Temperature & Humidity Control System
Temp. range Maximum:80ºC,120ºC;Minimum:-60ºC,-50ºC,-40ºC,-30ºC,-20ºC,-10ºC,0ºC
Humidity Range 10%,20%,30%~95%
Temp. constancy ±0.5ºC
Humidity constancy ±2.5%R.H
Temp. uniformity ±2.0ºC
Humidity uniformity ±5.0%R.H
Heat up time +20ºC~+80ºC ,Within 60 min
Pull down time +20ºC~-55ºC -40ºC-20ºC-10ºC ,Within 120 or 90 or 60 min
Interior material Stainless Steel Plate(SUS 304)
Exterior material Baked Painting Steel Or Stainless steel(SUS304)
Insulation material Rigid polyurethane foam
Door size (mm) Single wing:W800*H1800;Double wing:W1600*H1800;
Safety Devices(standard) No fuse breaker, over pressureover heat and over current protection for compressor,
over temperature protection, over load protection for blower, dry heat protection
Standard accessories Sight window*1,cable port(portΦ50mm)*1,chamber lamp*1, status indicator
Refrigeration system Water Cooled
Semi-hermetic compressor, single stage or cascade refrigeration system
CFC free refrigerant(HFC-507 and HFC-23)
Controller Panel 7-inch LCD Touch panel,Chinese or English display selectable
Operation model Program or fix point running
Memory capacity 120 programs,1200steps, all repeat 999 cycles,part repeat 99 cycles
Accuracy Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit
Input Temp.:pt-100, Humidity:pt-100 or ~5V DCV
Comm.port RS-232 or RS-485 (Softawre is option)
Ambient Temp. +5ºC~+35ºC
Wiring method AC 380±10%50Hz ,3 phase 4 wires +Ground Wires
Note:1. We reserve the right to change specifications without prior notice
2.Customized sizes and configurations available

 
4. Description
 

Optional accessories

●Cable Port: Two size of cable port is available: Φ50mm, Φ100mm.

●Double door

●Pass room: Provided to avoid disturbance of atmospheric temperature

and humidity while opening the door.

●Floor reinforcement: Can be fixed if heavy specimen placed in the

chamber for test.

●Carry-in inclined platform: Provided below the door to facilitate moving

of specimens in and out through the door.

●Entire ceiling blow-out duct

The extremely wide air inlet reduces the airflow rate (down to

apprrox.0.5m/s)

●Dehumidifier

The rotation regenerating dehumidifier (M-300)ensures precise control of

low humidity (21℃,23%RH)for electrostatic reliability tests.

●Temperature and humidity recorder

100mm width recording paper with 6 dots

180mm width recording paper with 12 dots

●Status indication lamp

Provide to signal chamber status and warnings when normal running,

a malfunction running or stand by occurs.

●Water purifier

Provided to keep the humidifier heater free from scale and ensure the

supply of water to humidifier.

●Power socket

●Air cooled type condense

 

 

Standard Met and Implemented:

 

GB/Bb T2423.2-89 high temperature test method

GB2423.1-89 test A: low temperature test method 6

GJB150.4-1986 test at low temperature

IEC60068-2-1 low temperature test method

IEC60068-2-38 temperature cycle

IEC60068-2-78 constant humidity temperature

 
 
Packing Details:
We use PP Film wrapping the test chamber to protect the test chamber from moisture or being scratched first, then use strong plywood case for easyload and transport, and to keep the chambers from potential crash or impact.
 
 
After-sale Service:
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer.

Standard / Custom Solid Walk-in chamber for photovoltaic modules testing 0

Standard / Custom Solid Walk-in chamber for photovoltaic modules testing 1

Contact Details
KOMEG Technology Ind Co., Limited

Contact Person: Peter Zhang

Tel: +8615818392160

Send your inquiry directly to us (0 / 3000)