Temperature Range: | -70℃ ~ +150℃ | Temperature Deviation: | Temperature Deviation |
---|---|---|---|
Heating Rate: | From +20℃ To +150℃ 60min No Load | Cooling Rate: | From +20℃ To -65℃ 90min No Load |
Pressure Range: | 100KPa~1000Pa | Decompression Time: | 100KPa~1000Pa With 20min(no Load, Dry Inside Box) |
Interior Size: | W 450 × H 650 × D 700mm | Exterior Size: | W 760 × H 1770 × D 2350 Mm |
Compressor: | BOCK Semi-hermetic Compressors | Condenser: | Air Cooling Fin Condenser. (air Cooled) |
High Light: | high altitude chamber,portable altitude chamber |
Combined Temperature Altitude Humidity Testing Low-pressure Test Chamber
Summary
Altitude testing chamber is used for testing high temperature, low temperature, height, low and high cycle and temperature altitude test for products (components), parts and materials. The chamber can be used for the test of heat dissipation test sample and non heat dissipation test sample at the high and low temperature test. As to the test of heat dissipation test samples, the heating power should not exceed the refrigerating capacity of chamber. As a dynamist value, refrigerating capacity change with temperature change.
Standard
GB/T2423.2-2008 high-temperature test Bb
GB-2423.21-2008 Low pressure test M
GB/T2423.26-2008 high-temperature test/ Low pressure comprehensive test Z/BM
GJB150.2A-2009 Low pressure (height )test (Test procedureⅠ/Ⅱ/Ⅲ)
GJB150.2A-2009 High-temperature test
GJB150.6A-2009 temperature height test
Main features:
1.Outer wall material: High-quality carbon steel with static color spray
2. Inner wall material: SUS304 # matte stainless steel plate
3. Insulation materials: Rigid polyurethane foam insulation layer + glass fiber.
4. Door Single door: Heating wire was installed at the door frames to prevent condensation at low temperatures.
5. Observation window: Observation window W210*H270 mm, there are lights inside
6. Condensate water outlet: Equipped with condensing water and condensate drainage unit
7. Lead hole and terminal: Φ100mm*1 located on left side and sealed with glass sintering terminal(24-cell 10A) flange 1.
8. Gas valve: Gas valve used pressure relief by hand when power out
9. Sample holder: Two layers of stainless steel sample holder, load capacity 20kg/layer
10. Air Heater inside: Finned heat pipe-shaped stainless steel heater
11. Heater: High-quality nickel-chromium alloy wire electric heater, non-contact control (SRR).
Specification
Model | KU205S | KU1000S | KU4500L |
Internal volume | 205L | 1000L | 4.5m3 |
Inside Dimension | W 45 × H 65 × D 70cm | W100*H100*D100cm | W150*174*D173cm |
Outer Dimension | W 76 × H 177 × D 235 cm | W181*H209*D266cm | According to the design |
Temp. range | -70~+100℃ | -70~+100℃ | -40~+100℃ |
Temperature fluctuation | ±0.5℃ | ≤0.5℃(Atmospheric pressure, no load) | ≤0.5℃(Atmospheric pressure, no load) |
Temperature deviation |
≥100℃,±3.0℃ (normal pressure, no load) <100℃, ±2℃ (normal pressure, no load) |
≤±2.0℃(Normal pressure, no load) | ±2℃( normal pressure, no load) |
Heating uptime | Heating and cooling rate 0.7℃~1.0℃/ min(Full average) | ||
Cooling time | |||
Pressure range | Atmospheric pressure~0.5KPa | Atmospheric pressure~0.5KPa | Atmospheric pressure~0.5KPa |
Blood pressure rate | Atmospheric pressure~1KPa≤30min (environmental temp.) | Atmospheric pressure~1KPa≤30min (Dry inside box, no load) | Atmospheric pressure~1KPa≤30min (Dry inside box, no load) |
Recovery rate | ≤10KPa/min | ≤10KPa/min | ≤10KPa/min |
Safety protection device | |
Cooling System |
A. Compressor overheat protection Heater dry combustion protection switch B. Compressor overcurrent protection C. Compressor high pressure protection |
Chamber |
A. Adjustable over temperature protection B. Test space temperature fuse C. Air conditioning channel ultimate over temperature protection D. Fan motor overheating protection E. Heater overcurrent circuit breaker |
Other security protection |
A. Phase sequence and phase loss protection B. Leakage protection, overload and short circuit protection C. Vacuum pump over-current, overload protection |
Besides this, we have a lot of other chambers for your reference:
3-zone/ 2-zone Thermal Shock Chamber
Walk-in Constant Temp. And Humidity Chamber
Rapid Temp. Change Chamber
Precise Drying Test Chamber
Temperature/ humidity/ vibration three integrated Chamber
Precise Drying Chamber
Vacuum oven/ no oxidation oven
Air Exchange Type Aging Oven
Burn-in Room
Salt spray Chamber
Vibration Testing Machine( mechanical and electromagnetic)
FAQ
Q1: What is the Warranty for the accelerated aging machine?
A1: For the accelerated aging machine, we offer 1 year warranty service. If any quality problems on our side occurred in this period, we will send you the replacement and cover the cost of shipping and component parts.
Q2: What's the delivery term?
A2: Usually, it takes us 20 - 25 days after order confirmation to produce the equipment and a little bit longer for customization service. While if you are in urgent need, we can make a special arrangement to speed up the proceedings. Then we start the shipped by sea, by air freight or by air express.
Q3: What’s the payment term?
A3: T/T, L/C, and other payment terms could be negotiated.
Q4: Is it ok for customization service?
A4: Yes, the inner chamber dimensions, structure, color, some special parameters can be customized as per your specific request.
Contact Person: Anna Hu
Tel: +8618098282716